Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Venue: UCI Beall Applied Innovations - Venture Cove B

Location: 5141 5270 California Avenue Suite 100, Irvine, CA 92697 (Free parking in the lot)

...

Contact: Hooshang Nayyeri (hnayyeri@uci.edu) and Vivian U (vivianu@uci.edu)


...

HW3 - 

ETC


Exercise 1 exploration:

o What do you think the “out-of-date” field in the workbook list means?

  • version control 

o Try to find out how you can share a workbook with a collaborator. Experiment with read and write permissions.

  • Add user by email, permission checkboxes


Exercise 2 exploration:

o Find the known issues under the help menu. Which one, if any, do you think could most affect your favorite science case?

  • For IFU calculations, which allow the user to choose between two strategies, changing the strategy for a selected calculation will revert to the default settings to the newly selected strategy. All previous user inputs in the strategy tab will be lost. (#1072)
  • The extinction calculation assumes a simple relationship between the magnitude and the column density. It is correct for a source with a smoothly varying or reasonably flat input flux density.  It will be inaccurate for sources with extremely steep gradients.(#1884)
  • NIRSpec noise is underestimated in some readout patterns.(#2429)
  • The ETC allows detector parameters that may lead to large exposure times. Users are advised to check with APT and choose detector parameters accordingly. (#2099)
  • For near-infrared detectors, APT allows 1 group per integration, but the ETC does not because the magnitude of systematic errors will not be known until measurements are made in orbit. (#246)


Exercise 3 exploration:

o Note the two different slopes in the signal-to-noise ratio (SNR) for increasing the number of groups and increasing the number of integrations. What do you think

causes this behavior?

  • integration takes longer because it includes readout time in between

o Experiment with other readout patterns (under the Detector Setup tab) to find the highest SNR for a total exposure time of about 1000 seconds. What is it?

  • medium8


Exercise 4 exploration

o A scene can contain multiple sources. Using the “Offset” parameter in the scene, determine the minimum unblended separation of a binary star for your chosen

NIRCam imaging filter.

  • ??


Exercise 5 exploration

o What is the faintest point source that will yield a “SOSS or AMI faint” target acquisition without a warning for NIRISS?

  • 14 mJy at 1.3 microns


Exercise 6 exploration

o What if you knew that the surface brightness of Pluto at 3 micron is 1000 MJy/sterad. How would you renormalize the spectrum to this value?

  • "Source Editor" → "Renorm", and "Shape" → "Surface Brightness"


Exercise 7 exploration

o How can the “Groups Before Saturation” image help you quickly determine the optimal number of groups?

  • It displays the min. number of groups before saturation - usually at source center where the surface brightness peaks.

o How much exposure time is needed to observe Pluto with the NIRSpec IFU in high resolution at 2.7-5.2 micron with a minimum SNR of 20?

  • about 300 seconds


Exercise 8 and 9 exploration

o Create a new workbook and share it with a colleague. Now delete your version of the workbook. What happens with your colleagues’ version?

  • done


...

HW2 - 

Understanding JWST detectors questionnaire

...