You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Date

Attendees

Goals

Discussion items

TimeItemWhoNotes
Simulated Data
 Bright Target Acquisition (TA) 
  • NIRCam TA uses medium filter (F335M) and NGROUPS=3
  • Saturation limit is K=7.02
  • 4 GTO targets exceed this limit (HD 189733, HD 209458, HD 149026, GJ 436)
  • Implementation of a narrow filter for TA improves limit by ~2.5 mag, but won't likely be possible until Cycle 2
  • Option A: TA on offset target
    • Positive: Requires no additional capabilities
    • Negative: Limited to < 30" separation, requires both positions be know very precisely, faintness limits
  • Option B: TA on saturated target
    • Positive: No offset uncertainty, better pointing consistency, doesn't require nearby offset star
    • Negative: May require changes to flag saturated pixels
SystemOffset Distance (")Offset Jmag
HD 18973311.510.1
HD 20945832.915.7
HD 14902620.413.9
GJ 43626.416.4

Proposal Instructions for JWST
  • Waiver for exposure limit on MIRI TSO imaging
  • Implement new Special Requirement "Time Series Observation" for some JWST templates

JWST Documentation
  • Many JDox pages are going live tomorrow (May 19th)
  • Instrument team members should review relevant pages and supply feedback if changes are needed
  • Still working on TSO landing page that provides a broad overview and directs users to additional pages for more detailed information

Action items

  •  
  • No labels